Home
Journal Publications
Preprints &
Conference Records
Press Release
HDR Thesis
PhD Thesis
Master Thesis
Internship Reports
Patents

Preprints & Conference Records

Hybrid Pixels & Spectral CT

F. Cannet et al. Preneoplastic behaviours in hepatocellular carcinoma: cellular and moleculartraits in quiescent versus evolving lesions, to appear in Abstract Book. EMIM 2023, 14-17 Mar, Salzburg, Austria

F. Cannet, Deep-learning data processing of spectral PC-CT longitudinal studies to design and optimize combined immuno-anticancer treatments in liver cancer mouse models, R&D Seminar - "Imaging 2022", Institute Marseille Imaging (IMI), 26-30 Sep. 2022, Marseille, France

F. Cannet et al., Micro photon-counting computed tomography to document longitudinally treatment response in hepatocellular carcinoma mouse models, in Abstract Book. EMIM 2022, 15-18 Mar, Thessaloniki, Greece

S. Tairi et al., Simultaneous reconstruction and separation in a spectral CT framework with a proximal variable metric algorithm, in Proc. CT 5th Meeting, May 20-23 2018, Salt Lake City, USA, F. Noo Ed., pp. 32-35

L. Portal et al., Longitudinal in vivo monitoring of hepatocellular carcinoma in mice with photon counting computed tomography, in Abstract Book. EMIM 2018, 20-23 Mar, San Sebastian, Spain

L. Portal et al., First in-vivo monitoring of hepatocellular carcinoma in mice with a photon counting detector for micro-CT imaging, in Abstract Book. EMIM 2017, 5-7 Apr, Koeln, Germany

A. Habib et al., Simulation results for PLATO: a prototype hybrid X-ray photon counting detector with a low energy threshold for fusion plasma diagnostics, in Conf. Rec. iWoRiD 2016, 3-7 Jul, Barcelona, Spain, JINST 12 (2017) C01036

F. Cassol et al., Characterization of the imaging performance of a micro-CT system based on the photon counting XPAD3/Si hybrid pixel detectors, in Abstract Book. EMIM 2016, 8-10 Mar, Utrecht, Netherlands

C. Morel , Nuclear and CT imaging: what drives it?, in Abstract Book. EMIM 2016, 8-10 Mar, Utrecht, Netherlands

S. Tairi et al., Simultaneous reconstruction and separation in a spectral CT framework, in Conf. Rec. IEEE NSS/MIC 2016, 29 Oct-6 Nov, Strasbourg, France, IEEE Press

F. Cassol et al., A large surface X-ray camera based on XPAD3/CdTe single chip hybrids, in Conf. Rec. iWoRiD 2015, 28 Jun-2 Jul, Hamburg, Germany, JINST 10 (2015) C11010

C. Kronland-Martinet et al., Development of K-edge spectral tomography using XPAD3 composite pixels, in Conf. Rec. IEEE NSS/MIC 2014, 8-15 Nov, Seattle, Washington State, USA, IEEE Press

M. Dupont et al., Component separation for spectral X-ray imaging using the hybrid pixel camera XPAD3, in Conf. Rec. IEEE NSS/MIC 2013, Oct 27-Nov 2, Seoul, Korea, IEEE Press

H. Ouamara et al., Comparison of the performance of the photon counting hybrid pixel camera XPAD3 versus the CDD camera DALSA XR-4 for cone-beam micro-CT, in Conf. Rec. IEEE NSS/MIC 2012, 29 Oct-3 Nov, Anaheim, California, USA, IEEE Press

F. Cassol Brunner et al., Comparison of K-edge versus standard absorption imaging using the XPAD3 hybrid pixel detector , in Conf. Rec. IEEE NSS/MIC 2011, 23-29 Oct, Valencia, Spain, IEEE Press

C. Morel, F. Debarbieux, Développement de détecteurs à pixels hybrides pour le comptage de rayons X : une ouverture vers la tomodensitométrie spectrale, in Comptes-Rendus Sfμ 2011, 27 juin-1er juillet, Strasbourg, France, ed. par M. Schmutz, pp. 197-200

K. Medjoubi et al., Performance and applications of the CdTe- and Si-XPAD3 photon counting 2D detector, in Conf. Rec. iWoRiD 2010, 11-15 Jul, Cambridge, UK, JINST 6 (2011) C01080

A. Dawiec et al., Development of a PCI express based readout electronics for the XPAD3 X-ray photon counting imager, in Conf. Rec. IEEE RT 2010, 24-28 May, Lisbon, Portugal, IEEE Press, pp. 1-3

F. Cassol et al., Study of the charge sharing effect in the photon-counting pixel detector XPAD3-S, in Conf. Rec. iWoRiD 2009, 29 Jun-3 Jul, Prague, Czech Republic, Nucl. Instr. Meth. Phys. Res. A 633 (2011) S111-S113

A. Dawiec et al., Development of the XPAD3 X-ray photon counting imager DAQ electronics, in Conf. Rec. ANIMMA 2009, 7-10 Jun 2009, Marseille, France, IEEE Press, pp. 1-3

F. Cassol Brunner et al., Measured imaging performance of photon counting hybrid pixel X-ray detectors, in Conf. Rec. IEEE NSS/MIC 2008, 19-25 Oct, Dresden, Germany, IEEE Press, pp. 4700-4703

J.-F. Bérar et al., XPAD3 hybrid pixel detector applications, in Conf. Rec. iWoRiD 2008, 29 Jun-3 Jul, Helsinki, Finland, Nucl. Instr. Meth. Phys. Res. A 607 (2009) 233-235

B. Chantepie et al., The XPAD3 detector: a fast hybrid pixel detector for small animal X-ray imaging, in Conf. Rec. OCS 2008, 17-19 Mar, Cannes, pp. 107-108

P. Pangaud et al., First results of XPAD3, a new photon counting chip for X-ray CT-scanner with energy discrimination, in Conf. Rec. IEEE NSS/MIC 2007, Honolulu, Hawaii, 27 Oct-3 Nov, IEEE Press, pp. 14-18

R. Khoury et al., A geometrical calibration method for the PIXSCAN micro-CT scanner, in Conf. Rec. ITBS 2007, 22-28 Sep, Milos Island, Greece, JINST 4 (2009) P07016

F. Cassol Brunner et al., Simulation of PIXSCAN, a photon counting micro-CT for small animal imaging, in Conf. Rec. ITBS 2007, 22-28 Sep, Milos Island, Greece, JINST 4 (2009) P05012

P. Pangaud et al., XPAD3-S: a fast hybrid pixel readout chip for X-ray synchrotron facilities, in Conf. Rec. iWoRiD 2007, 22-26 Jul, Nuernberg, Germany, Nucl. Instr. Meth. Phys. Res. A 591 (2008) 159-162

S. Hustache-Ottini et al., The hybrid pixel single photon computing detector XPAD, in Conf. Rec. SRI 2006, 28 May-2 Jun, Daegu, Korea, AIP Conf. Proc. 879 (2007) 1087-1090

P. Delpierre et al., XPAD: a photons counting pixel detector for material sciences and small-animal imaging, in Conf. Rec. PISA 2006, 21-27 May, La Biodola, Elba Island, Italy, Nucl. Instr. Meth. Phys. Res. A 572 (2007) 250-253

P. Delpierre et al., PIXSCAN: pixel detector CT-scanner for small animal imaging, in Conf. Rec. EuroMedIm 2006, 9-12 May, Marseille, France, Nucl. Instr. Meth. Phys. Res. A 571 (2007) 425-428

P. Pangaud et al., XPAD3: a new photon counting chip for X-ray CT-scanner, in Conf. Rec. EuroMedIm 2006, 9-12 May, Marseille, France, Nucl. Instr. Meth. Phys. Res. A 571 (2007) 321-324

S. Valton et al., Evaluation of tomographic reconstruction methods for small animal microCT and microPET/CT, in Conf. Rec. EuroMedIm 2006, 9-12 May, Marseille, France, Nucl. Instr. Meth. Phys. Res. A 571 (2007) 278-281

P. Delpierre et al., PIXSCAN: pixel detector CT-scanner for small animal imaging, in IEEE NSS/MIC 2005, 23-29 Oct, San Juan, Puerto Rico Island, IEEE Press, pp. 2381-2385

S. Basolo et al., XPAD: Pixel detector for material Sciences, in IEEE NSS/MIC 2004, 16-22 Oct, Rome, Italy, IEEE Press, pp. 4388-4391

J.-C. Clémens et al., Pixel modules for X-ray experiments, in Conf. Rec. ICATPP 2001, 15-19 Oct 2001, Como, Italy

P. Delpierre et al., Pixel detector for X-ray experiments, in Conf. Rec. ECM 1999, 17-18 Jun, Grenoble, France

P. Delpierre et al., Protein crystallography at the SLS, in Conf. Rec. Workshop on Pixel detector 1998, 9-10 Nov, Villigen, Switzerland

PET & Hybrid Tomography

J. Nuyts, E. Roncali, S. Gundacker, C. Morel and P. Lecoq, Estimating the relative SNR of individual TOF-PET events for Gaussian and non-Gaussian TOF-kernels, in Proc. Fully-3D 2021, 19-23 Jul, Leuven, Belgium, G. Schramm, A. Rezaei, K. Thielemans and J. Nuyts eds, pp. 97-102

P. Lecoq, C. Morel and J. Prior, Case for setting up a 10 ps challenge: A step toward reconstruction-less TOF-PET, in Conf. Rec. MEDAMI 2019, 15-17 May, Valencia, Spain, Il Nuovo Cimento 43 C (2020) 2

M. Hamonet et al., The ClearPET/XPAD prototype: development of a simultaneous PET/CT scanner for mice, in Conf. Rec. IEEE NSS/MIC 2015, 31 Oct-7 Nov, San Diego, California, USA, IEEE Press

R. Becker et al., Monte-Carlo simulation based estimation of NECR, sensitivity, and spatial resolution of a novel preclinical PET insert for MR, in Conf. Rec. IEEE NSS/MIC 2015, 31 Oct-7 Nov, San Diego, California, USA, IEEE Press

S. Nicol et al., Design and construction of the ClearPET/XPAD small animal PET/CT scanner, in IEEE NSS/MIC 2009, 25-31 Oct, Orlando, Florida, IEEE Press, pp. 3311-3314

S. Nicol, S. Karkar, P. Descourt, C. Morel, The ClearPET/XPAD: development of a simultaneous PET/CT scanner for mice, in Conf. Rec. ESMI TOPIM 2009, 26-30 Jan, Les Houches, France, p. 29

M. Khodaverdi et al., Design study for the ClearPET/XPAD small animal PET/CT scanner, in IEEE NSS/MIC 2007, 27 Oct-3 Nov, Honolulu, Hawaii, IEEE Press, pp. 4300-4302

M. Rey et al., Count rate performance study of the Lausanne ClearPET scanner demonstrator, in Conf. Rec. EuroMedIm 2006, 9-12 May, Marseille, France, Nucl. Instr. Meth. Phys. Res. A 571 (2007) 207-210

M. Khodaverdi et al., High resolution imaging with ClearPETTM Neuro - First animal images, in IEEE NSS/MIC 2005, 23-29 Oct, San Juan, Puerto Rico Island, IEEE Press, pp. 1641-1644

M. Rey et al., Measured and simulated specifications of the Lausanne ClearPET scanner demonstrator, in IEEE NSS/MIC 2005, 23-29 Oct, San Juan, Puerto Rico Island, IEEE Press, pp. 2070-2073

D. Wisniewski et al., Digital pulse shape discrimination methods for phoswich detectors, in IEEE NSS/MIC 2005, 23-29 Oct, San Juan, Puerto Rico Island, IEEE Press, pp. 2979-2983

S. Weber et al., Image reconstruction for the ClearPET Neuro, in Conf. Rec. ITBS 2005, 25-29 Sep, Milos Island, Greece, Nucl. Instr. Meth. Phys. Res. A 569 (2006) 381-385

E. Auffray et al., The ClearPET project, in Conf. Rec. ITBS 2003, 26-30 May, Milos Island, Greece, Nucl. Instr. Meth. Phys. Res. A 527 (2004) 180-189

Monte Carlo

L. Cappellugola et al., Update of the optical light transport in Geant4 to model optical coating, Geant4 Technical Forum, 27th Geant4 Collaboration Meeting, 27 Sep 2022, Rennes (virtual), France

B. Mehadji, M. Dupont, D. Fougeron and C. Morel, Monte Carlo simulation of a scintillation crystal read by a SiPM with GATE, NDIP20, 9th Conference on New Developments in Photodetection, 4-8 Jul 2022, Troyes, France, Nucl. Instr. Meth. Phys. Res. A 1048 (2023) 167905

L. Cappellugola et al., Modelisation of light transmission through surfaces with thin film optical coating in Geant4, in Conf. Rec. IEEE NSS/MIC 2021, 16-23 Oct, Yokohama (virtual), Japan, IEEE Press

J. Bert et al., Hybrid GATE: a GPU/CPU implementation for imaging and therapy applications, in Conf. Rec. IEEE NSS/MIC 2012, 29 Oct-3 Nov, Anaheim, California, USA, IEEE Press, pp. 2247-2250

H. Perez-Ponce et al., Implementing Geant4 on GPU for medical applications , in Conf. Rec. IEEE NSS/MIC 2011, 23-29 Oct, Valencia, Spain, IEEE Press

C. Morel, La simulation Monte Carlo en médecine nucléaire, in Comptes-Rendus ACOMEN 2007, 9-10 mai, Nice, France, Médecine Nuléaire 31 (2007) 160-164

L. Simon et al., Simulation of time curves in small animal PET using GATE, in Conf. Rec. ITBS 2003, 26-30 May, Milos Island, Greece, Nucl. Instr. Meth. Phys. Res. A 527 (2004) 190-194

K. Assié et al., Monte Carlo simulation in PET and SPECT instrumentation using GATE, in Conf. Rec. ITBS 2003, 26-30 May, Milos Island, Greece, Nucl. Instr. Meth. Phys. Res. A 527 (2004) 180-189

G. Santin et al., GATE, a Geant4-based simulation platform for PET integrating movement and time management, in Conf. Rec. IEEE NSS/MIC 2002, 10-16 Nov, Norfolk, Virginia, USA, IEEE Press, pp. 1325-1329

D. Strul, G. Santin, D. Lazaro, V. Breton and C. Morel, GATE (Geant4 Application for Tomographic Emission): a PET/SPECT general-purpose simulation platform, in Conf. Rec. Siena 2002, 21-24 Oct, Siena, Italy, Nucl. Phys. B-Proc. Suppl. 125 (2003) 75-79

Compton Camera & Prompt Gamma Imaging

M.Z. Hmissi, G. Lebonvallet, A. Iltis, B. Mehadji and C. Morel, Compton 3D imaging with sparse number of views: progress on image quality @ 511 keV, to appear in Abstract Book EANM 2021, 20-23 Oct, Hamburg (virtual), Germany, suppl. EJNMMI

C. Caplan et al., A μTCA back-end firmware for data acquisition and slow control of the CLaRyS Compton camera, in Conf. Rec. IEEE NSS/MIC 2019, 28 Oct-2 Nov, Manchester, UK, IEEE Press

X. Chen et al., A time-of-flight gamma camera data acquisition system for hadrontherapy monitoring, in Conf. Rec. IEEE NSS/MIC 2019, 28 Oct-2 Nov, Manchester, UK, IEEE Press

B. Mehadji et al., Extension of the list-mode MLEM algorithm for poly-energetic imaging with a Compton Camera, in Conf. Rec. IEEE NSS/MIC 2018, 10-27 Nov, Sydney, Australia, IEEE Press

H.Z. Hmissi et al., First images from a CeBr3/LYSO:Ce Temporal imaging portable Compton camera at 1.3 MeV, in Conf. Rec. IEEE NSS/MIC 2018, 10-27 Nov, Sydney, Australia, IEEE Press

X. Chen et al., A data acquisition system for a beam-tagging hodoscope used in hadrontherapy monitoring, in Conf. Rec. IEEE NSS/MIC 2017, 21-28 Oct, Atlanta, USA, IEEE Press

A. Iltis et al., Temporal imaging of CeBr3 Compton camera: a new concept for nuclear decommisionning and nuclear waste management, in Conf. Rec. ANIMMA 2017, 19-23 Jun, Liège, Belgium, EPJ Web of Conferences 170 (2018) 06003

A. Iltis et al., Temporal imaging: observation and localization of a Compton effect inside a 20 mm monolithic LYSO plate with a Philips digital Si-PM, in Conf. Rec. IEEE NSS/MIC 2016, 29 Oct-6 Nov, Strasbourg, France, IEEE Press

J. Krimmer et al., Development of a Compton Camera for medical applications based on silicon strip and scintillation detectors, in Conf. Rec. NDIP 2014, 30 Jun-4 Jul, Tours, France, Nucl. Instr. Meth. Phys. Res. A 787 (2015) 98-101

C. Abellan, J.-P. Cachemiche, F. Réthoré, A data acquisition system for medical imaging, in Conf. Rec. ANIMMA 2013, 23-27 Jun, Marseille, France, IEEE Press

Beta Microprobe

F. Gensolen et al., MAPSSIC, a communicating MAPS-based intracerebral positrons probe for deep brain imaging in awake and freely-moving rats, in Conf. Rec. ANIMMA 2019, 17-21 Jun, Portoroz, Slovenia, EPJ Web of Conferences 225 (2020) 09002

J. Heymes et al., IMIC - Needle-shaped low-power monolithic active pixel sensor for molecular neuroimaging on awake and freely moving rats, in Conf. Rec. IEEE NSS/MIC 2016, 29 Oct-6 Nov, Strasbourg, France, IEEE Press


Legal mentions

Webmaster : F.Cassol